The short answer
A propane generator for home backup draws on cylinders when it's a portable, or on a tank when it's a standby unit. A 20 lb cylinder holds about 4.7 gallons: divide that by your spec sheet's propane gallons an hour for hours per cylinder. A tank is filled to about 80 percent, so size it backward from the days you need.
Why propane, and what it asks of you
Our page on which fuel fits your house sets propane beside gasoline and natural gas. Propane's edge is simple: it keeps. It's stored as a liquid under pressure in a sealed tank, with no 30-day clock like gasoline, so you can fill it in the off-season and leave it.
What it asks in return is a little arithmetic, and a look at each cylinder before you count on it, because a few checks decide whether it gets refilled at all.
A portable on cylinders or a standby on a tank
| Portable on cylinders | Standby on a tank | |
|---|---|---|
| What it runs | What you plug in, or key circuits through a transfer switch an electrician installs | Up to the whole house, switched over without you |
| What it needs | Someone home to roll it out, start it and swap cylinders | A pad, a tank on site, a gas line to the unit, and a way for the delivery truck to reach the tank |
| The outage it fits | A day or two, with blocks of running | Long or frequent outages, or a house that's often empty |
The standby side, from the automatic switch to the spot and the size, is on whole house generator. The fuel math below covers both.
Spec-sheet lines besides fuel use
- Running and starting watts on propane. A dual-fuel label rates each fuel on its own, so if propane is what you'll store, hold your list against the propane lines, using what size generator do I need.
- The outlet that meets the house. To feed house circuits, a portable's cable plugs into an outlet wired to the transfer switch, so check the generator has the matching outlet. Ask the electrician which one that is. For a standby, check that the automatic switch it's sold with covers the circuits you chose.
- The fuel connection. Check which cylinder sizes the portable's hose and regulator are made for. A standby is piped from the tank by your propane supplier or a licensed gas fitter.
Hours from one cylinder
Cylinders are named by pounds, but you plan in gallons. A 20 lb cylinder holds about 4.7 gallons, a 34 lb about 7.9 and a 100 lb about 23.6. That works out to about 4.2 pounds a gallon.
- Find the propane fuel use on your generator's spec sheet, at the load you expect. If it's listed in pounds an hour, divide by 4.2 to get gallons.
- Divide the cylinder's gallons by that number. That's your hours per cylinder.
No propane line on the sheet? Estimate it from gasoline. Most portables burn about half to three-quarters of a gallon of gasoline an hour, and a gallon of propane carries about 91,452 Btu against gasoline's 120,214. So propane needs roughly 1.3 times the gallons for that work, about 0.65 to 1 gallon an hour.
| Cylinder | Gallons | Run time at 0.65 to 1 gallon an hour (estimate) |
|---|---|---|
| 20 lb | 4.7 | about 5 to 7 hours |
| 100 lb | 23.6 | about 24 to 36 hours |
Your spec sheet's number replaces the estimate as soon as you have it.
Cylinders for three days
Stretch the same arithmetic to three days:
- Propane gallons an hour, times the hours a day you'll run it.
- Times 3 days.
- Divided by 4.7 for 20 lb cylinders, or 23.6 for 100 lb. Round up.
An example with made-up numbers, so use your own: 0.8 gallons an hour, run in blocks for 8 hours a day, is 6.4 gallons a day and about 19 for three days. That's five 20 lb cylinders. The same generator running nonstop needs about 58 gallons, or thirteen of them.
Then hold the count against your town's limit. Where the limit is 25 gallons of portable cylinders, with empty ones counted as full, that's five 20 lb cylinders or one 100 lb. So under a limit like that, block running fits and nonstop running doesn't. A longer outage on cylinders means more refills, or a tank.
A standby tank, sized backward
A home tank is named by its total size and filled to about 80 percent, which leaves room for the liquid to expand on hot days. A full 500-gallon tank holds about 400 gallons.
To size one:
- Take the generator's propane use in gallons an hour from its spec sheet. Full load gives the worst case.
- Multiply by 24 and by the days you want covered.
- Add what the furnace, water heater and range burn over those days, if they share the tank.
- Divide the total by 0.8. That's the smallest tank that holds it when full.
An example with made-up numbers: 2 gallons an hour for 5 days is 240 gallons, so at least a 300-gallon tank for the generator alone. Add the furnace's gallons to the 240 before you divide. The supplier and installer confirm the size and where the tank may sit. Ask them to check it against your coldest nights too: small tanks lose pressure in cold weather, so the tank has to keep the generator and the furnace fed at full load, not just hold the gallons. Reading the gauge as hours on storm day, and the call-in mark to settle with your supplier, are on how long can a whole house generator run.
The date on the collar decides the refill
Propane keeps. The cylinder doesn't, at least on paper.
- Look for the date stamped on the collar, month and year. A cylinder has to be requalified within 12 years of that date, then every 5 to 12 years depending on the method. A later date followed by an "E" is good for 5 years, and one followed by an "S" for 7. Overdue cylinders must not be refilled.
- Refillers also turn a cylinder away for cracks or leaks, bulging, major dents or gouges, and damaged valves or foot rings.
- Check the valve. Most cylinders with an overfill prevention device have a triangular hand wheel marked "OPD", and in many states a cylinder without one can't be refilled.
Do this on a quiet weekend, not the day before a storm, and swap or requalify any cylinder that fails.
Where spare cylinders live
- Outside, not in the garage or anywhere indoors, even in winter.
- Out of strong heat. Heat builds pressure until the relief valve lets propane out, so not beside the grill or the fireplace.
- At least 10 feet from stored gasoline and other flammable liquids.
Propane has a smell added on purpose, ethyl mercaptan, so a leak gets noticed. If you smell it, everyone leaves the house, then someone calls 911 from a distance.
Propane still makes carbon monoxide
Propane burns cleaner than gasoline, but the exhaust still carries carbon monoxide.
- A portable runs outdoors only, at least 20 feet from the house, with its exhaust aimed away from windows, doors and vents. It never runs in a garage, basement, crawlspace or shed, and not on a porch or in a carport.
- Refuel only with the engine off and cooled down, and treat a cylinder swap the same way.
- For a propane standby unit, ask for a spot at least 25 feet from every window, door and vent, soffit vents included.
- Put battery-powered or battery-backup carbon monoxide alarms on every level and outside every sleeping area. If one sounds, get everyone outside, then call 911.
- Generator power reaches the house wiring only through a transfer switch or interlock a licensed electrician installs. Never through a wall outlet, and never into the panel without one. The hookup choices for a portable are on hooking up a generator to your house.
Questions people ask
Can a portable run from the big tank that feeds my house?
Only through an outdoor connection that your propane supplier or a licensed gas fitter installs, with the regulator the generator needs. Don't improvise with grill hoses, and the generator still sits at least 20 feet from the house.
Sources
Every number in this article comes from these public sources, and we checked each one before it went up.
- New York State Office of General Services - Propane contract 23398, cylinder sizes in gallons
- EIA - Energy units and calculators explained
- UF/IFAS Extension - Portable generators, know watt's right and wrong
- Propane Education and Research Council - Storing propane fuel, lesson 9
- PHMSA - Cylinder requalification flyer, hosted by Oklahoma State University
- Lehi Fire Department, Utah - Home fuel storage limits
- DOE Alternative Fuels Data Center - Propane fuel basics
- Ready.gov - Life-saving skills toolkit, gas emergencies
- OSHA - Portable generators fact sheet FS-3286
- CPSC staff - Stationary generators, the carbon monoxide poisoning hazard and recommendations for mitigation, June 2025
- CPSC - What to know about generators and carbon monoxide, 2022
- CDC - Carbon monoxide poisoning basics
- Utah Be Ready - Generator
- DOE Building America Solution Center, PNNL - Generators for back-up power during outages, updated 2021