Power outages and backup power
CPAP Battery Backup - How Many Nights a Battery Runs Your CPAP
Updated October 12, 2026 - 7 min read - Rainy Day Plan
The short answer
A CPAP battery backup keeps your machine running when the power goes out. Size it from your CPAP's watts: watts x hours of sleep x nights x 1.2. At our planning number of 65 W, with the heated humidifier and tube on, one 8-hour night uses about 520 Wh, so plan about 650 Wh of battery per night.
Three ways to run a CPAP on battery
This page is about the machine and its power. Settings, pressure and anything about your therapy stay with your equipment supplier and your care team.
A battery made for your model. Some CPAP makers sell a battery pack that fits their machine. It's small and light - fine for travel and a single night. Ask your supplier how many hours it gives at your settings.
Then there's the portable power station, a larger battery box with wall-type outlets and often a 12-volt port. It can run a CPAP for several nights and keep phones and a lamp going on the side.
A DC cable. Many CPAPs can take a DC cable made for the model, plugged into a power station's 12-volt port. It skips the station's inverter and the CPAP's power brick, and each of those loses some power as heat, so the same battery lasts longer. Your supplier can tell you whether one exists for your model.
Whichever you lean toward, check first that your device can run from a battery or a generator: read the user instructions, or call your supplier or the device maker.
Step 1: find your CPAP's watts
- Look for a watts (W) number on the CPAP or on its power brick, the box on the cord.
- No watts? Find the OUTPUT line on the brick and multiply volts x amps. Example: 24 V x 2.5 A = 60 W.
- Skip the INPUT line. That's the wall side, not the device.
- Call your supplier and ask: "How many watts with the heated humidifier and heated tube on, and with them off?"
A label often shows the most a device can draw, so sizing from it gets you a bigger battery than you need. That's the right way to be wrong. A test night (step 4) gives your real number.
Our planning number is 65 W, with the humidifier and heated tube on. It's a planning estimate, not the watts of any model.
Step 2: do the runtime math
Hours = battery Wh, divided by CPAP watts, x 0.85. The 0.85 takes off about 15% for losses inside the battery and its outlet.
Take a 1,000 Wh power station and a 65 W CPAP. 1,000 divided by 65 is about 15 hours, and 15 x 0.85 is about 13 hours. That's about one and a half 8-hour nights.
Two devices on one battery? Add their watts first. A 65 W CPAP plus a 10 W phone charger is 75 W.
Step 3: size it for 1, 2 or 3 nights
Battery Wh = watts x hours of sleep x nights x 1.2. The 1.2 is our planning factor for losses: some of the stored energy turns to heat on the way out and never reaches your devices. It also leaves room for long nights and batteries that fade with age.
| CPAP watts | Wh for 1 night | Wh for 2 nights | Wh for 3 nights |
|---|---|---|---|
| 20 W | 200 | 400 | 600 |
| 40 W | 400 | 800 | 1,200 |
| 65 W | 650 | 1,250 | 1,900 |
| 80 W | 800 | 1,550 | 2,350 |
That's math only: 8-hour nights x 1.2, rounded up. The watts are round numbers, not any model's spec.
A three-night battery covers a 72-hour outage, which is where most family plans start. Size it with the watts for the humidifier and heated tube on. Whether running without them for a few nights is fine for you is a question for your supplier or care team, so ask it on a calm day and write the answer down.
Before you buy: compare two batteries line by line
Store pages lead with different numbers. Put these side by side for each battery you're looking at:
- Watt-hours. Many packs list only milliamp-hours, which isn't the same thing. Ask for the Wh, and run it through step 2.
- The outlet your CPAP uses. A wall-type outlet, and whether your supplier says your machine needs a pure sine wave one. Or a DC port with the volts your model's DC cable needs.
- Output watts. Our rule of thumb: at least your CPAP's watts x 1.25.
- Automatic switchover. If the power cuts at 3 a.m., a station that takes over by itself keeps the CPAP going without anyone moving a plug. Ask how fast it switches, and test it in step 4.
- Recharge time from the wall, from a car and from a solar panel, in hours.
- Weight, if you'll carry it to the car or to a place with power.
- How many charge cycles it's rated for, and the warranty years.
The battery with the bigger box isn't always the one with more nights. Compare nights, from step 2, before anything else.
Step 4: run a test night
One normal night on battery turns our planning number into your real one, and finds a missing cable while stores are open.
- Charge the station to 100%. Plug in only the CPAP.
- Sleep a normal night with your normal setup. Keep the wall cord within reach.
- In the morning, write the % left. % used = 100 minus % left.
- Real Wh a night = station Wh x % used, divided by 100.
- Nights you can count on = 100 divided by % used, rounded down.
Say a 1,000 Wh station drops to 60%. That's 40% used, 400 Wh a night, so 2 nights you can count on.
Any alarm, error, or a CPAP that won't start on battery? Call your supplier before you rely on it.
Recharging between nights
A battery buys nights. Recharging buys days.
Wall power is for the days before: charge it to full when a storm is in the forecast, and check it once a month. Write down the date and the %.
From the car, use the station's car cable with the engine running and the car outdoors. A car socket charges slowly, so plan on several hours in daylight with someone awake.
Folding solar panels can refill a station too. Panel watts = Wh a night, divided by 4 sun hours, x 1.3. For a 520 Wh night, that's about 170 W of panels on a sunny day.
A generator is for houses only, and its rules are at the end of this page. Apartments and condos: no generator.
To compare a power station with an installed home battery, see the runtime tables in home battery backup.
Calls to make before the outage
Make these on a calm day, not during the storm.
Your equipment supplier:
- Can my CPAP run from a battery power station or a generator? How many watts does it draw?
- Is there a battery or DC cable made for my model? Which outlet does it use?
- If it stops in the night, what do I do, and what's your 24-hour number?
Write every answer down and keep it with the battery.
Your electric company: tell it you have a medical device that needs power, and ask to be put on its list for priority restoration. Ask what the list does and doesn't promise. Crews still need time, so keep your own battery either way.
Your local emergency office: ask where places with power or charging open in a long outage.
During the outage, and when power returns
- Switch the CPAP to the battery and write the time and the battery %.
- Morning and evening, log the %. Nights left = % left divided by % used a night.
- Recharge in daylight. The CPAP and one phone come first.
- When the power comes back, check that your CPAP's settings haven't changed. Medical devices often reset to a default mode when power is cut. If they have, call your supplier.
When to go somewhere with power
Set your leave line now: less than one night of battery left and no recharge coming. Leave in daylight, before the last night runs out. Head for a friend's home with power, or for the charging stations and warming or cooling centers communities often open in a long outage.
Trouble breathing or chest pain? Call 911 first. The power plan comes second.
The first hours of an outage are in power outage, and the supplies list is in power outage emergency kit. An oxygen concentrator is a different plan: it draws far more power than a CPAP and may run around the clock, so start that one with your oxygen supplier.
Car, generator and battery rules for the bedroom plan
- Never run a car in an attached garage to recharge, even with the door open.
- A generator runs outdoors, more than 20 feet from windows, doors and vents, with the exhaust pointed away from the house, never in a garage or basement. Put battery CO alarms on every level of the home, and turn it off and let it cool before refueling.
- Never plug a generator into a wall outlet. House circuits only through a transfer switch a qualified electrician installed.
- Charge lithium-ion batteries only between 32°F and 105°F, store them at room temperature, and keep them out of hot cars and direct sun.
- Check for water before you plug anything in. Don't plug in a cord if the cord or the device is wet.
Questions people ask
Can a phone power bank run a CPAP?
Usually not. Phone power banks charge phones over USB and hold far less energy than a CPAP needs for a night. Read the outlet type and the Wh on the label, and ask your supplier before you count on one.
Can one battery run the CPAP and the fridge?
Only a big one. A fridge at our planning number of 1,440 Wh a day uses nearly three CPAP nights of energy every day. Put the CPAP first, and give the fridge whatever's left after the CPAP's nights are covered.
Sources
Every number in this article comes from these public sources, and we checked each one before it went up.
- FDA - Tips about medical devices and natural disasters
- Ready.gov (FEMA) - People with disabilities
- Ready.gov (FEMA) - Power outages
- American Red Cross - Power outages: prepare, during and after
- CDC - Carbon monoxide poisoning basics
- US Fire Administration - Battery fires: charging and storing lithium-ion batteries
- OSHA - Portable generators fact sheet FS-3286