Power outages and backup power
How Much Gas Does a Generator Use - Fuel for a 3-Day Outage, Worked Out
Updated October 17, 2026 - 6 min read - Rainy Day Plan
The short answer
Most portable generators use about half to three-quarters of a gallon of gas an hour, or 12 to 18 gallons a day if they never stop. Three days nonstop takes 36 to 54 gallons. Running in blocks of a few hours cuts that to 6 gallons a day or less, an amount you can store and rotate.
Why the number matters before the storm
If you haven't settled on a fuel yet, our page on natural gas, propane and gasoline for a house weighs all three. This one sticks to gasoline: the gallons it takes, and how to keep them fresh. If yours is a standby unit on natural gas or a propane tank, what it burns and how long it lasts are on how long can a whole house generator run.
Two facts make it worth ten minutes now. Your town may cap the gasoline you keep at home: where the limit is 25 gallons, that's a day and a half to two days of nonstop running at 12 to 18 gallons a day. And gasoline may be in short supply before, during and after a disaster, because an outage can close gas stations too. The gas in your car's own tank doesn't count toward a home limit like that one, so fill the car before a storm as well as the cans.
Your generator's own number
The 12-to-18 figure is an average. Yours is on the spec sheet: the tank size in gallons and the run time on a full tank at half load. Divide gallons by hours.
An example with made-up label numbers: a 6-gallon tank and 10 hours at half load is 0.6 gallons an hour, inside the range above. Two cautions go with it. Half load isn't full load, and the harder the engine works, the more it burns. And big engines are thirsty anyway: a large generator will easily use 1 gallon an hour with light loads, and running one for several days after a hurricane or ice storm could take 50 to 100 gallons.
So size the generator before you stock fuel for it. The watts are added up on what size generator do I need.
Three days of fuel: 36 to 54 gallons nonstop, 5 to 18 in blocks
At half to three-quarters of a gallon an hour:
| Plan | Hours a day | Gallons a day | Gallons for 3 days |
|---|---|---|---|
| Nonstop | 24 | 12 to 18 | 36 to 54 |
| 2 hours on, 4 hours off, day and night | 8 | 4 to 6 | 12 to 18 |
| Daytime blocks; perishables in a cooler with ice overnight | 6 | 3 to 4.5 | 9 to 14 |
| One 3-hour block that charges a power station | 3 | 1.5 to 2.25 | 5 to 7 |
Every block plan fits inside a 25-gallon limit like the one above. Nonstop running doesn't. What makes blocks work:
- The fridge sets the rhythm. Shut, it keeps food cold for about 4 hours without power, and a thermometer inside should read 40°F or below. So keep the gaps to 4 hours at most, and let the thermometer have the last word: if it reads above 40°F during a gap, start the generator early, and keep each block running until it's back to 40°F or below.
- A battery in the middle saves the most fuel. The generator fills a power station during one block, and the station runs the fridge and lights quietly the rest of the day. Size the station first, so it carries them until the next block, fridge start-up surge included; the math is on portable power station. Then check its charging input: refilling 2,000 Wh in a 3-hour block takes about 800 W (2,000 x 1.2 / 3).
- Medical devices don't wait for the next block. Plan a battery for them, and ask your equipment supplier what fits.
The fuel worksheet
Six lines on a card, filled in from your own spec sheet and your own town.
- Gallons an hour: tank gallons divided by run-time hours at half load.
- Times the hours a day you'll run it, from the table above.
- Times 3 days, or the days your outages usually run.
- Divided by your can size, rounded up. That's the cans you need full.
- Compared with your fire department's limit. Over it? Shorten the blocks, add a battery, or make propane the second fuel.
- Divided by the months between rotations. That's the gallons a month you have to burn in the car to keep the stock fresh.
Line 6 is the one people skip. Untreated gasoline should be used within 30 days, so untreated cans mean emptying all of them into the car every month. With a stabilizer, rotate every 3 to 6 months, sooner if its label says so. As an example, 15 gallons rotated every 3 months is 5 gallons a month into the car, about one ordinary fill-up's worth.
How much gasoline you may keep, and where
Your local fire department sets the limit, so call it before you stock up and ask three things: the total, how much may sit in an attached garage, and whether a basement is allowed. Where the total is 25 gallons, no more than 10 may be in an attached garage and none in a basement, in approved containers only.
- A ventilated shed or detached garage, out of the reach of children. Never in the house.
- Approved containers only. Red for gasoline, labeled, with a spout that pours without spilling. Never glass jars or milk jugs.
- Gas cans made since July 2023 must have a flame mitigation device, which guards against flame jetting and the can rupturing. If yours are older, replace them with newer spill-proof ones.
- Check for leaks once a month.
Untreated gasoline gets 30 days
- Date every can the day you fill it.
- No stabilizer? Use it within 30 days. Pour it into the car and refill the can on your next trip.
- With a stabilizer, add it when you buy the gas, and check the product is made for gasoline with ethanol. Follow the time on its label.
- Storing for more than a month? Keep the can about 95% full, which leaves room to expand but little air for moisture.
- Don't store gas in the generator. Most makers don't recommend leaving gasoline in power equipment for more than a month. Run it dry before you put it away.
- Gas that sat too long but isn't gummy or dirty can go into the car mixed one part old to five parts new. Gas that's gummy, dirty or has water in it goes to a household hazardous waste collection day. Never onto the ground or into a drain.
Refuel cold, and keep the exhaust outside
- Turn the generator off and let it cool before you pour. Fuel spilled on hot engine parts can catch fire.
- Store the cans away from heat and flame too: the generator itself, water heaters, cigarettes, lighters and matches.
- A portable runs outdoors only, at least 20 feet from the house, with its exhaust aimed away from windows, doors and vents. It never runs in a garage, basement, crawlspace or shed, and not on a porch or in a carport.
- Put battery-powered or battery-backup carbon monoxide alarms on every level and outside every sleeping area. If one sounds, get everyone outside, then call 911.
- The house wiring takes generator power only through a transfer switch or interlock that a licensed electrician installs. Never plug a generator into a wall outlet or the panel.
Questions people ask
How long will a generator run on 5 gallons of gas?
About 7 to 10 hours at half to three-quarters of a gallon an hour. Your manual's half-load run time gives the figure for your own model, and a bigger engine or a heavier load shortens it.
Does the same math work for a diesel generator?
No. Diesel has its own rule of thumb: about 0.07 gallons an hour for each kW of generator size. A 10 kW diesel generator running around the clock uses about 17 gallons a day.
What if propane is my second fuel?
A dual-fuel generator lets you save the gasoline and burn propane, which has no 30-day clock. The cylinder math is in propane generator for home.
Sources
Every number in this article comes from these public sources, and we checked each one before it went up.
- UF/IFAS Extension - Portable generators, know watt's right and wrong
- Mississippi State University Extension - Disaster relief, emergency standby electric generators, P2972
- Lehi Fire Department, Utah - Home fuel storage limits
- Maine Department of Environmental Protection - Tips for handling gasoline
- CPSC - Flame mitigation devices required on gas cans and other portable fuel containers, January 2023
- OSHA - Portable generators fact sheet FS-3286
- CDC - What to do during a power outage
- FDA - Food and water during power outages and floods, PDF
- FEMA Emergency Management Institute - Operational generator fueling requirements, course IS-815
- FEMA - Generators at home fact sheet, October 2022
- Ready.gov - Power outages
- CDC - Carbon monoxide poisoning basics
- CPSC - What to know about generators and carbon monoxide, 2022
- Utah Be Ready - Generator