Power outages and backup power
Whole House Generator - How It Works, What Size, Which Fuel and Where It Sits
Updated October 17, 2026 - 5 min read - Rainy Day Plan
The short answer
A whole house generator is a permanent engine on a pad outside, also sold as a home standby generator. When the grid fails, it starts by itself and feeds your panel through an automatic transfer switch, burning natural gas or propane. Two choices matter more than the model: how much of the house it carries, and how far it sits from your windows.
The first minute of an outage, in order
Here's what happens when the lights go out:
- The automatic transfer switch senses the outage and signals the generator to start. The generator takes over the load.
- While it runs, the switch keeps its power from flowing back into the utility lines.
- When the grid comes back, the load moves back and the switch tells the engine to stop.
Nobody has to be home for any of it. That's the whole case for a standby unit over a portable, and it's also why one can run for days with nobody watching.
It isn't silent between outages either. The switch may start the engine for a self-test, for example once a week for about 15 minutes. So you'll get noise and exhaust on ordinary days too.
"Whole house" is a size, and your list sets it
Sellers quote sizes in kilowatts (kW). One kW is 1,000 watts. The jump from "the essentials" to "the whole house" is bigger than most people expect. Here's how a list grows, in typical running watts. Your own appliances will differ, so read it as an example.
| What's on the list | Running watts |
|---|---|
| The essentials: refrigerator/freezer, 1/3 hp well pump, furnace fan, four LED bulbs, two phone chargers, a laptop | 2,560 |
| Add a microwave oven | 1,000 |
| Add a window air conditioner, 12,000 BTU | 3,250 |
| Add an electric water heater | 4,500 |
| Everything above | 11,310 |
Three appliances took the running load to more than four times the essentials. Hot water and cooling are what "whole house" buys. The fridge, the pump, the furnace fan and the lights were covered already.
Central air, an electric range and a clothes dryer aren't even on that list. So decide the list before the size. The sum, with your own labels, is on what size generator do I need.
The last word on your size isn't a chart. The electrician works out the load for the permit, and it can't go over the generator's rating. As a yardstick, the standby units on Louisiana homes after Hurricane Ida ran from 10 to 24 kW, and 22 kW was the most common size.
Natural gas or propane, and how long it runs on each
Pick by what already reaches the house. On natural gas it runs as long as gas reaches the meter. It's also the usual pick: of the 53 Ida units whose fuel was known, 49 ran on natural gas and 4 on propane. Propane is the answer where there's no gas line, and then the tank decides how long you've got.
The engine sets a limit of its own, through oil and running hours. For the fuel math for a day, a worked tank example and a routine from day 1 to day 5, see how long a whole house generator can run.
What sets the price of yours
Budget for the work more than the box. The installation usually costs more than the generator itself, and a smaller unit doesn't shrink it much. No national figure will match your quote, because the work depends on your house. So have every installer price the same seven lines in writing: the generator, the transfer switch, the electrical work, the fuel hookup, the site work, the permits and inspections, and the yearly service. Then compare the quotes line by line, not by the total. How to check installers and weigh their bids is on whole house generator installation.
Standby or a portable on a switch: what changes on outage night
| Standby unit | Portable on a transfer switch or interlock | |
|---|---|---|
| When the power fails | Starts by itself, home or away | Someone rolls it out, starts it and moves the switch |
| Fuel | A natural gas line or a propane tank | Refueled by hand, engine off and cool |
| Where it runs | A fixed spot on a pad | Outdoors, at least 20 feet from the house, every time |
| Who puts it in | Licensed trades, under a permit | A licensed electrician for the switch, under a permit |
Whether the standby route pays off at your address is a separate question, and is a whole house generator worth it works it through. It turns on how long your outages run, what gets damaged while the power's off, and whether someone would be home to start a portable. One hard limit comes before all of that, though. The yard.
Where it sits: 25 feet from every window, door and vent
Settle the spot before the quote, and measure it from every opening:
- Ask for a spot at least 25 feet from every window, door and vent, soffit vents included. Our own minimum is 20 feet from the house, for any generator.
- If the plan shows 5 feet, hold out for the 25. That 5 is a fire code number. Installers work to it, but at Louisiana homes after Hurricane Ida, exhaust traveled at least 25 feet, far past it.
- Have the contractor quote that spot from the start. Moving a unit later means doing the wire and gas work twice.
- Put battery-powered or battery-backup carbon monoxide alarms on every level and outside every sleeping area. If one sounds, get everyone outside, then call 911.
An engine in the yard feels like it can't hurt anyone indoors, which is why the distance gets trimmed. After Ida, carbon monoxide (CO) got indoors in 256 Louisiana homes. A portable was the source in 65, and the home's own standby generator in 105. In 85 of those 105 homes a CO alarm went off, and in 12, people had symptoms. After Hurricane Beryl in 2024, another 153 reports named a stationary generator as the CO source.
Noise: ask for the decibels and the distance
A standby unit isn't quiet. Ask for the decibel rating and the distance it was measured at, because a number without a distance tells you little. As a yardstick, one city's faster permit path is open only to units no louder than 67 decibels at 23 feet. For scale, a lawn mower runs at around 85 to 90 decibels.
The self-test makes that noise on ordinary days, so ask the installer to set it for a weekday afternoon rather than a weekend morning.
Upkeep runs on a calendar, not on memory
Skip the maker's schedule and the unit can fail early and leave you with no power in an outage. The monthly look-over and the full table are on whole house generator maintenance.
Hookup and exhaust rules for standby and portable alike
Either way, a generator feeds the house wiring only through a switch that a licensed electrician installs under a permit: an automatic transfer switch for a standby unit, a transfer switch or interlock for a portable. Never plug a generator into a wall outlet or the panel. A portable runs outdoors only, at least 20 feet from the house, with its exhaust aimed away from windows, doors and vents. It never runs in a garage, basement, crawlspace or shed, and not on a porch or in a carport.
Sources
Every number in this article comes from these public sources, and we checked each one before it went up.
- CPSC staff - Stationary generators, the carbon monoxide poisoning hazard and recommendations for mitigation, June 2025
- DOE FEMP - Standby generators and automatic transfer switches
- Eugene Water & Electric Board (EWEB) - Generator sizing considerations, worksheet
- City of North Port, Florida, Building Division - Generator permit guidelines
- CPSC - What to know about generators and carbon monoxide, 2022
- CDC - Carbon monoxide poisoning basics
- OSHA - Portable generators fact sheet FS-3286
- Utah Be Ready - Generator
- PNNL - Operations and maintenance best practices, standby generators