Power outages and backup power
Home Generators for Power Outages - Four Kinds Compared, Then the First Hour
Updated October 17, 2026 - 7 min read - Rainy Day Plan
The short answer
Home generators for power outages come in four kinds. An open-frame portable runs a few chosen things for as long as you keep pouring fuel. An inverter portable runs a shorter list, more quietly. A standby unit starts by itself and suits frequent outages. A battery power station runs small things indoors for hours. Size yours to a must-run list, and run engines 20 feet out.
Four kinds side by side: which one fits your outages
Find your outage in the last column and read back across the row. Once you know the kind, size it with what size generator do I need, then pick the model by its spec sheet.
| Kind | What it runs | How long it runs | What it needs | The outage it fits |
|---|---|---|---|---|
| Open-frame portable | A few chosen circuits or appliances, more on a bigger frame | As long as you keep fueling it, at about half to three-quarters of a gallon an hour | Fuel cans, a spot 20 feet out, cords, or a transfer switch from a licensed electrician | A day or two up to a week, if you can store and pour the fuel |
| Inverter portable | A short list: the fridge, lights, electronics. Quieter at light loads, quick to overload when a motor starts | As long as you keep fueling it | Fuel, a spot 20 feet out, cords, or a transfer switch on the bigger models | A few hours to a day or two, where noise counts |
| Standby unit, installed outside | Chosen circuits up to the whole house, through an automatic transfer switch | On natural gas, as long as gas reaches the meter; on propane, until the tank is empty. Ask the maker how many hours in a row it's built for | A gas line or propane tank, a pad outside, licensed trades and a permit | Frequent outages, long ones, or nobody home to start a portable |
| Battery power station | Phones, lights, the router, a fan, a fridge for a while. Not central air or a well pump | Until the battery runs down; the hours math is on its page | A full charge before the storm, then the wall or solar panels to refill it. No exhaust, so it stays indoors | A few hours, or the nights while a generator rests |
Once you have one: the first hour with a portable
A standby unit starts by itself. Check that it's running, keep the load to what it was sized for and watch the gauge if it's on a propane tank. The rest of this page is for a portable, where a person does the work.
Where the generator sits at 7 p.m. is where it'll be at 3 a.m., so the spot gets chosen while it's light. The night is when it goes wrong: after four hurricanes hit Florida in 2004, about two of every three people treated for carbon monoxide (CO) poisoning reached the emergency room between 5 and 10 in the morning. Nearly all of the cases traced back to portable generators, and most happened overnight.
Minute 0 to 10: do you need it yet?
A short outage in mild weather may not need the generator at all. Start setting up if the outage will likely run past the fridge's 4 hours with the door shut, a sump pump has to keep up with the storm, the house is getting too hot or too cold for someone in it, or a medical device is on its backup. For that last one, follow the outage plan you made with the doctor or equipment supplier.
Minute 10 to 25: the generator goes out, the alarms get tested
- Roll it to its spot in the yard, 20 feet or more from the house, exhaust facing away from windows, doors and vents. The garage, basement, crawlspace, shed, porch and carport are all out, even with doors open.
- Check that the ground is level and there's 3 to 4 feet of air on every side and above. Raining? Give it an open-sided canopy, never a closed box.
- Check the oil and top up the fuel while the engine is cold, outside.
- Press the test button on every CO alarm. Battery ones belong on every floor and outside the bedrooms.
- Close the windows on the generator's side of the house.
- Lay the cords: the heavy outdoor kind with three prongs, rated for what they'll carry, no cuts. They need to reach the full distance, so the generator never creeps closer to meet a short one.
Minute 25 to 40: start it empty, then add one thing at a time
With cords:
- Start the engine with nothing plugged in, the way your manual describes.
- Plug in the fridge first, alone. Its motor pulls two to three times its running watts for a moment as it starts.
- Then the freezer. Then the small things: lights, the router, chargers. Give each a moment before the next.
- A microwave or coffee maker runs one at a time and gets unplugged after.
- Listen. If the engine bogs down or the generator's breaker trips, unplug the last thing you added. An overloaded generator can overheat and start a fire.
Write that order on a strip of tape and stick it on the generator. Nobody reads a manual by flashlight.
One at a time only covers the first start, though. After that, the fridge and freezer switch on by themselves, sometimes in the same second. If the generator's starting watts can't cover both at once, keep only one of them plugged in at a time.
With a transfer switch or interlock, follow the steps your electrician left at the panel. On an interlock it usually goes like this. Plug the cord into the generator and the inlet with the engine off. Turn off every breaker, then the main. Start the generator. Slide the interlock over and turn the generator breaker on. Then switch on only the circuits that can't wait, one at a time. Too many at once tends to shut a portable down. The order for a transfer switch, and the way back for both, are in hooking up a generator to the house.
Never plug a generator into a wall or dryer outlet. Power sent back that way can run out along the lines and electrocute the utility crews working on them.
Minute 40 to 60: the fuel, the blocks and two house rules
A generator in an outage is a daily chore, not a switch. Settle the routine before dark.
Start with the fuel. Your spec sheet gives a run time on a full tank at half load. Divide the tank's gallons by those hours to get gallons an hour, then multiply by the hours you'll run it each day. Most portables burn about half to three-quarters of a gallon an hour, so running nonstop eats 12 to 18 gallons a day. One can for a three-day outage won't last.
Running it in blocks stretches that a long way. The fridge only needs power often enough to stay at 40°F or below, so put a thermometer inside and let it decide. Charge phones, power banks and any power station during every block.
The refuel rule doesn't bend: engine off, cooled down, then pour, outside. The fuel itself stays in approved cans, away from living areas and never in the house.
Then tell everyone two rules. Nobody moves the generator closer. If a CO alarm sounds, everyone goes outside, then someone calls 911.
| When | What to do |
|---|---|
| Morning | Read the fridge thermometer, check the oil, refuel while the engine is cold |
| Daytime | Run the fridge and freezer, charge every battery in the house |
| Before dark | Last refuel of the day, test the CO alarms, chain and lock the generator |
| Night | Run it or rest it (next section) |
Overnight: run it or rest it?
People who are asleep can die from CO poisoning before they have any symptoms. That's why the night gets its own decision.
Resting it means shutting it down at bedtime. Read the fridge thermometer first, and shut down only once it shows 40°F or below. Then the fridge clock starts again: about 4 hours with the door shut, shorter than most nights. So move the milk and meat to a cooler with ice before bed, and read the thermometer first thing in the morning. A battery power station charged during the day can carry phones, a lamp or a fan indoors.
Running it means the full 20 feet, the exhaust pointed away, windows on that side shut, and a working battery CO alarm outside every sleeping area. Fill the tank before bed so nobody pours fuel on a hot engine at 3 a.m.
Check those alarms twice. In the fatal cases where it was known whether a CO alarm was present, only 16% had one, and in almost half of those it couldn't work: dead, missing or wrongly installed batteries, or a plug-in alarm with the power out.
When the power comes back
- With a transfer switch or interlock, switch back in the order your electrician gave you, while the engine is still running. On cords, unplug what the generator was feeding.
- Shut the engine down as the manual says, then unplug the cord from the inlet if you used one.
- Let the generator cool before you move or cover it.
- Refill the cans outside, and write down what didn't work while you still remember.
Sources
Every number in this article comes from these public sources, and we checked each one before it went up.
- CDC MMWR 54(28) - Carbon monoxide poisoning from hurricane-associated use of portable generators, Florida, 2004
- CDC - What to do to protect yourself during a power outage
- CDC - Carbon monoxide poisoning basics
- CPSC - What to know about generators and carbon monoxide, 2022
- CPSC staff - Fatal incidents associated with non-fire carbon monoxide poisoning from engine-driven generators and other engine-driven tools, 2010-2020
- OSHA - Portable generators fact sheet FS-3286
- Ready.gov - Power outages
- FEMA - Generators at home fact sheet, October 2022
- San Diego Gas & Electric (SDG&E), hosted by the City of San Diego - Facts you should know about portable electric generators, 2004
- DOE Building America Solution Center - Generators for back-up power during outages
- UF/IFAS Extension - Portable generators, know watt's right and wrong
- Mississippi State University Extension - Selecting small portable electric generators, IS1921