Power outages and backup power
Sump Pump Battery Backup - How to Size One and Test It
Updated October 17, 2026 - 7 min read - Rainy Day Plan
The short answer
A sump pump battery backup keeps water leaving the basement when the power fails. There are two kinds: a second 12-volt pump with its own deep-cycle battery and charger, or a battery power station that runs the pump you have. For the first, pick a battery near the pump maker's maximum, typically around 120 amp-hours.
The storm that fills the pit also cuts the power
Heavy rain raises the water under the floor and knocks out power lines in the same hours. So the pump tends to lose its power right when the pit is filling. That's the gap a battery backup is there for.
If you're backing up more than the pump, home battery backup covers the rest of the house. Here it's just the pump: which kind, how big, and how you'll know it works.
A second pump, or a battery for the pump you have
| A 12-volt backup pump | A battery that runs your main pump | |
|---|---|---|
| What it is | A second pump in the same sump, with its own battery and charger | A portable power station, or an installed home battery, feeding the pump you have |
| Starts by itself | Yes. It runs only if the main pump fails | Only if it's set up to switch over on its own |
| Covers a broken main pump | Yes | No |
| Sized by | Battery amp-hours | Watt-hours, output watts and surge watts |
| Other uses | None | The fridge, phones and lights when the pit is dry |
A main pump can stop for reasons that have nothing to do with an outage. Common failures are worn or rusted motor bearings and a float switch that no longer makes good electrical contact. Only the second-pump kind covers those.
There's also a backup pump driven by city water pressure, with no battery at all. Ask a plumber whether your home and water service suit one.
Sizing the 12-volt kind
- Use a deep-cycle lead-acid battery as the everyday battery. It's built for the long, repeated draining a backup pump does.
- The amp-hour rating decides the hours of protection. Buy one near the maximum the pump maker recommends, typically around 120 amp-hours.
- Use the charger that came with the backup pump.
- If the battery runs down in an emergency, a standard vehicle battery can power the backup pump as a stand-in. Check the backup pump's manual for how its leads connect to another battery, plus to plus and minus to minus, and tape a note of it by the pit before you need it.
To compare with a power station, turn amp-hours into watt-hours: 120 amp-hours x 12 volts = 1,440 Wh on the label.
How many hours the 12-volt pump runs
The amp-hours set the hours of protection; how often the pump runs sets how fast they go. Work out your own:
- Battery Wh = amp-hours x 12.
- Pump watts: from the backup pump's label, or its amps x 12 (volts x amps = watts).
- Minutes per hour: time the main pump in a heavy rain (next section). Most new pumps have a chart in the manual or on the box with the flow at each height of lift. If the backup moves fewer gallons at your lift, it runs longer: multiply your minutes by the main pump's gallons, then divide by the backup's. If that comes near 60 minutes an hour, the backup can barely keep up with the water, and a bigger battery won't change that. Look for a backup pump that moves more water at your lift.
- Average watts = pump watts x minutes per hour, divided by 60.
- Hours = battery Wh, divided by 2, divided by the average watts.
The 2 is our planning factor for a lead-acid battery: count on about half of what its label holds, and less as it ages. A 120 amp-hour battery leaves about 720 Wh to plan on. Twice the minutes, half the hours.
Sizing a power station for the pump you have
How often the pump runs matters more than how big it is. You need three numbers.
Start with running watts. Read the pump's label: watts, or amps x 120, the volts of a standard US plug. Can't reach the label? Use the sump pump rows of the chart on what size generator do I need: about 800 W to run for a 1/3 horsepower pump and 1,050 W for a 1/2.
Next, starting watts. A motor needs a short burst well above its running power to start. Ask the pump maker for the real starting number first. Without it, use the check from the same page: four times the running watts, about 3,200 W for a 1/3 horsepower pump and 4,200 W for a 1/2. The chart's own starting figures come out lower, and too little starting power is what shuts a station off. The station's surge rating has to be above that number, and its continuous output at least running watts x 1.25. If it isn't, the station shuts off the first time the pump kicks on.
Last, and the one that matters most: minutes per hour. A sump pump works in short bursts. During a heavy rain, time it: how many seconds it runs, and how many times in 10 minutes. Multiply out to minutes per hour, and write it on the pit lid.
Then: Wh a day = running watts x minutes per hour, divided by 60, x 24. Battery to buy = Wh a day x the days you want x 1.2.
For a 1/2 horsepower pump at 1,050 W:
| The pump runs | Wh a day | Battery for one day | Hours from a 1,440 Wh station |
|---|---|---|---|
| 2 minutes an hour | 840 | about 1,000 Wh | about 34 |
| 5 minutes an hour | 2,100 | about 2,500 Wh | about 14 |
| 10 minutes an hour | 4,200 | about 5,000 Wh | about 7 |
| 20 minutes an hour | 8,400 | about 10,000 Wh | about 3 1/2 |
| 30 minutes an hour | 12,600 | about 15,000 Wh | about 2 1/4 |
These are planning estimates, rounded, and each start uses a little extra.
The same battery lasts six times longer at 5 minutes an hour than at 30. A slow, steady seep suits a battery. A pit that fills as fast as the pump can empty it needs a generator outdoors or an installed system.
One more check. A power station only helps if the pump is plugged into it when the power fails. Choose one with automatic switchover and set it up the way its manual says, or accept that someone has to be home to move the plug. If you're often away in storm season, the 12-volt backup pump is the better fit, because it needs nobody.
Test the pump and the backup in 10 minutes
Do it before the wet season, and again every six months, when the battery check is due too.
- Outside, check that the discharge pipe isn't blocked and sends water away from the house, not next to the foundation.
- Check that the pump is plugged in. Lift the lid and look for debris with a flashlight.
- Pit dry? Pour in water at about the rate it normally arrives, until the float trips. The pump should start and run smoothly.
- Lifting the float by hand for about 10 seconds runs the pump dry, so test that way only if the pump's manual allows it.
- Watch the pump turn on and off at least twice.
- Then run the backup on its battery alone. With the battery fully charged, shut off power to the main pump and to the backup's charger, and pour water in until the backup pump comes on. Turn both back on when you're done.
- Check the battery for corrosion and write the date on it. A worn battery can still show a full charge and run far fewer hours, so don't go by the charge light. Replace it at the life its maker states, or sooner if in step 6 the backup pump runs slower than before or stops before the pit is empty.
A pump that sounds like it's pumping gravel, or a float that moves sluggishly, may need replacing.
Where the battery sits
Keep the battery and charger up off the floor, on a wall shelf above the sump. A power station goes on a hard surface in a spot that stays dry, close enough that the pump plugs straight into it. A water alarm on the floor by the pit gives early warning.
When the outage outlasts the battery: generator rules
A long, wet outage is a job for a generator. But someone has to be home to start it. Many homes use a battery for the first hours and a generator for the long haul. Size it for the pump's starting watts with our what size generator do I need steps. The rules that come with it:
- Outdoors only, at least 20 feet from the house, with the exhaust pointed away from windows, doors and vents. Never in a garage or basement.
- Battery CO alarms on every floor. Refuel only when it's off and cool.
- Connect the pump with a heavy-duty extension cord, kept out of the water. Don't touch electrical equipment if it's wet or you're standing in water.
- Never plug the generator into a wall outlet to feed the house. Backfeeding can electrocute utility workers. A licensed electrician installs a transfer switch.
The pump is only one piece of a flood plan. What to pack and when to leave are in flood survival kit.
Sources
Every number in this article comes from these public sources, and we checked each one before it went up.
- NDSU Extension - Electric backup sump pumps for houses, quick tips for battery selection
- NDSU Extension - Check your sump pump, February 2020
- NDSU Extension - Time to check your sump pump, April 2013
- North Dakota Department of Emergency Services - Sump pump questions, from NDSU Extension
- DOE Building Science Education - Home electrification and electric panel upgrades
- NDSU Extension - Standby electric generators
- Ready.gov - Floods
- Ready.gov - Power outages
- DOE Office of Electricity - Electricity 101
- CDC - Carbon monoxide poisoning basics
- OSHA - Portable generators fact sheet FS-3286