RVs, campers and vans
How to Winterize an RV - The Order of Work, Antifreeze or Air, and a Checklist to Print
Updated October 12, 2026 - 9 min read - Rainy Day Plan
The short answer
To winterize an RV, empty the fresh, gray and black tanks, drain the water heater and set its bypass so no antifreeze goes into it, and open the low-point drains. Then fill the lines with pink RV antifreeze made for drinking-water systems, or blow them out with low-pressure air, one faucet at a time, cold side then hot. Finish with antifreeze in every drain and the toilet.
Antifreeze or air: which method fits your rig
Both work. They suit different winters.
Pink antifreeze fills every line, so the little bit of water hiding in a dip or a fitting can't freeze and split it. It's the simpler choice when the rig will sit through a long, hard freeze, or when you don't own a compressor. The catch is more jugs to buy, and a spring flush to get the taste out.
Air leaves nothing in the drinking lines, so spring start-up goes quicker. You need a compressor that holds its pressure, though, and the patience to clear each outlet until all it sputters is mist. Water can still sit in low spots, and air from the water inlet never reaches the drain traps. That's why the drains get antifreeze either way.
You can also do both. Blow the lines out first, then pump antifreeze, and there's less leftover water to thin it.
What to have on hand before you open a valve
- Pink RV antifreeze with a label that says it's for drinking-water systems. Not the stuff in your car's radiator. That's ethylene glycol, and it doesn't belong in any part of a water system.
- For the pump method, a way for the pump to drink straight from the jug. Some rigs come with a winterizing valve and tube next to the pump. If yours doesn't, a pump converter kit adds one.
- For the air method, a compressor with a pressure regulator, and a blowout plug that threads into the city-water inlet.
- A wrench that fits the water heater's drain plug, a bucket and a flashlight.
- The owner's manual. No two rigs put the valves, the bypass and the drains in quite the same place, so find yours before you start.
How much antifreeze to buy
Plan on 2 to 3 gallons for the pump method, drains and toilet included, as long as the heater bypass is set. That's our rough planning number: the lines take most of it, and that part depends on how many feet of line your rig has. If the owner's manual gives a number, go by that one. Buy one jug more and keep it sealed if it's left over.
Here's where it goes:
- For the lines, whatever it takes to push pink to every outlet. Count the cold and the hot side as two outlets so neither gets missed.
- About a cup down each sink, shower and tub drain, enough to replace the water its trap holds.
- About a cup in the toilet bowl, plus a little extra flushed down for the tank valves.
The drains and the toilet are the small part. Take a rig with four drains and a toilet, as an example: at a cup each, that's 5 cups, about a third of a gallon (our arithmetic: 16 cups make a gallon). If you use air, that share is all you need.
If you skip the bypass, the heater's whole tank fills before the first faucet runs pink, and the label on the heater tells you how many gallons that is. Write down how many jugs you used. Next fall you'll know your own number.
Step by step: drain everything first
- Empty the holding tanks at a dump station or your sewer hookup. Black tank first, then gray, so the gray water rinses the hose on its way out. Close both valves when they're empty.
- Unhook the city-water hose and switch the water pump off, so nothing refills the lines while they drain. Then open the fresh tank's drain and let it run dry.
- Switch the water heater off, electric and gas both, and give it time to cool all the way. Hot water under pressure is what you're waiting out.
- Lift the heater's pressure-relief lever at the top to let air in, then take out the drain plug at the bottom. On some heaters the plug is also the anode rod. Leave it out while the tank drains.
- Set the water heater bypass. It's usually two or three valves on the back of the heater, behind a cabinet door or an access panel. Turned to bypass, they send water and antifreeze around the heater's tank instead of through it. Forget this one and the tank fills with antifreeze before a drop reaches a faucet: gallons you'd buy only to flush out in spring.
- Open the low-point drains, usually one hot and one cold line under the rig. Then open every faucet, cold and hot, so air can get in behind the water. Run the pump only until it stops pushing water, then switch it off.
- Pull any water filter cartridges and drain their housings. They stay out until spring.
Pumping pink antifreeze to every faucet
- Close the low-point drains and every faucet. Check the heater bypass one more time.
- Put the pump's intake tube into the first jug. With no tube and no kit, you can pour antifreeze into the empty fresh tank instead. The pump needs a fair amount in there before it can draw, though, so you'll go through more.
- Switch the pump on. At the faucet nearest the pump, open the cold side until pink runs steadily, close it, then do the hot side.
- Work your way out to the farthest faucet: kitchen, bathroom sink, shower or tub. Swap jugs before one runs dry so the pump isn't pulling air.
- Outside shower or outside faucet: cold and hot, until pink. It's out of sight, which makes it the easy one to miss.
- Toilet: hold the flush pedal or button down until pink shows in the bowl.
- Crack each low-point drain for a moment until pink appears, then close it.
- The fridge's ice maker and a washing machine each have winter steps in their own manuals. Follow those rather than pumping antifreeze into them.
Blowing the lines out with air at low pressure
- Set the compressor's regulator before you connect anything. Keep it low, at or under the water pressure your owner's manual lists for the plumbing. Those lines and fittings were built for water pressure, not shop air.
- Thread the blowout plug into the city-water inlet and attach the air hose.
- Start with the low-point drains open to blow them clear, then close them.
- Open one outlet at a time, cold side then hot, until only mist comes out. Close it and move on: sinks, shower, outside shower, the toilet valve.
- Go around a second time. Water that settled back into the dips comes out on the second pass.
- Disconnect, then pour antifreeze down the drains. The air never went through the traps, so they still hold water. It never went through the pump either, and water left in the pump can freeze and split it: drain the pump or run a little antifreeze through it, the way your owner's manual shows.
Traps, the toilet and the tank valves
Every sink, shower and tub has a trap, the U-bend under the drain that always holds water. With the pump method the faucets already ran pink into them, and a cup on top won't hurt. Pour the toilet's share in and flush part of it down so the black tank's valve sits in antifreeze, and send a little down a sink for the gray tank's valve.
The rest of the rig: battery, propane, food, damp, mice and tires
Charge the house battery full, then switch it off at its disconnect, or take it out and keep it somewhere it won't freeze. Or leave it on a charger the way its maker's manual says. Lithium batteries have their own cold-charging limits, and those are in the manual too.
Close the valve on each propane tank and turn every propane appliance off.
Take out all the food, even the opened packages and the spices. Crumbs are what bring mice in. Wipe the fridge and freezer dry and prop their doors open so they don't sour or grow mold.
For damp, open the cabinet and closet doors so air moves, and look over the roof seams and window seals before the snow. A small leak has all winter to do its damage, with nobody there to see it.
Check where pipes and wires pass through the floor and walls. A mouse fits through a hole about the width of a pencil, 1/4 inch. Stuff small holes with steel wool and caulk around it to hold it in place.
Set each tire to the pressure on the vehicle's tire label, checked cold, meaning it hasn't been driven for at least three hours. Check them again before the first trip in spring.
A checklist to print and tape inside a cabinet door
- Holding tanks emptied, black then gray, valves closed
- Fresh tank drained
- Water heater off and cooled, relief lever open, plug out
- Water heater bypass set
- Low-point drains open, every faucet open, cold and hot
- Filter cartridges out, housings drained
- Antifreeze pumped to every outlet until pink, or lines blown out twice at low pressure
- Toilet run until pink
- Outside shower done, cold and hot
- Ice maker and washer done by their own manuals
- A cup of antifreeze down every drain and into the toilet
- Low-point drains closed
- Battery charged full, then off, out, or on its charger
- Propane tank valves closed
- All food out, fridge and freezer doors propped open
- Small holes stuffed with steel wool
- Tires set cold to the label pressure
- Jugs of antifreeze used this year: ___
Spring: de-winterizing and the first clean fill
- Open the rig and look for droppings before you settle in. If you find them, open the doors and windows and stay out for 30 minutes while it airs. Wear rubber or plastic gloves, don't sweep or vacuum, soak the droppings with 1.5 cups of household bleach in 1 gallon of water for 5 minutes, and wipe up with paper towels.
- Put the water heater's drain plug or anode rod back, close the relief lever, and set the bypass back to normal so water flows into the heater again. Close the low-point drains.
- Hook up the water and run every faucet, cold and hot, until there's no pink and no antifreeze taste. Flush the toilet until the bowl water is clear. Don't skip the outside shower.
- Keep a hot faucet open until water flows steadily with no sputtering, so the heater is full before you switch it on.
- Dump the antifreeze that went into the holding tanks at a dump station.
- Sanitize the fresh tank and the lines next: bleach by tank size and the steps. Filters go back in after that last flush.
- Test the alarms, check the propane fittings for leaks, and check the tires cold.
Staying in the rig this winter instead
Living aboard is the opposite job: you keep the water liquid instead of draining it. Skirt the bottom of the rig, ready-made or from rigid foam board, and seal where pipes and wires pass through. Keep the hose and the holding tanks from freezing with heat made for them, or fill the fresh tank and unhook the hose between fills. Inside, hold the humidity at 30 to 40 percent or lower, depending on how much condensation you see.
Heat with the built-in vented furnace, never an unvented heater. For a night without power, see how to stay warm without electricity.
Aboard in the cold: the oven, the alarms and the generator
Never use the gas oven for heat, and make sure the carbon monoxide and propane leak alarms work. A generator goes outdoors only, more than 20 feet from windows, doors and vents, exhaust pointed away from the rig. Sizing one for the heaters is its own job.
Questions people ask
What should I ask if a shop winterizes it for me?
Ask which method they use - air, antifreeze or both - and whether the water heater gets bypassed. Ask for a written list of what they did, including the ice maker, the washer and the outside shower. The battery, propane, food and tires may not be part of the job, so ask about those too, or tick them off yourself from the list above.
Sources
Every number in this article comes from these public sources, and we checked each one before it went up.
- Purdue Extension - Protect your plumbing and appliances during a winter power failure, February 1, 2022
- NDSU Extension - Preparing RVs for winter living, AE1510, May 2018
- CDC - How to seal up to prevent rodents, April 8, 2024
- CDC - How to clean up after rodents, April 8, 2024
- NHTSA - Tires
- CDC - Carbon monoxide poisoning basics, January 12, 2026